Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator Posted by: Honders
Video duration: 141 seconds Related: N/A Display Video Comments | Hide Video Comments | Add Comment |
Further Reading: Global Warming - Climate Change - Energy - Recycling - Pollution
Latest articles: Facts about solar energy ~ Pros and cons of solar energy ~ How does solar energy work ~ Solar energy advantages disadvantages ~ Types of energy ~ Advantages and disadvantages of nuclear energy ~ Who are the world's 1 renewable energy site? ~ How does recycling affect the environment? ~ Why is recycling so important? ~ Interesting recycling facts ~ Natural causes of global warming ~ Is global warming real? ~ Safe and clean energy ~ Effects of water pollution ~ Types of water pollution ~ Land pollution ~ Poems about pollution ~ Definition of climate change ~ Fiji social capital community meetings climate change


Latest comments made on this video:
By: yahaya alhassan. on 21 May 12, 18:53:29
How much will this cost?
By: yahaya alhassan. on 21 May 12, 18:44:16
I like this project. I? want to construct my own by having 24v dc motor to run my ac motor
By: svedr. on 26 Apr 12, 13:59:27
i may be? wrong and i use metric units not imperial but... P=1 x 9800kg/m^3 x 64m x 9,81m/s^2 x 0,157m^2/s= 965994W=965kW 20kW seems kinda low for 73% efficiency, although formula i used is for water turbines in general not pump-turbine
By: Honders. on 26 Apr 12, 01:54:43
My total system efficiency is 73% using a pump as turbine and a 3 phase motor as generator. If I were to use a pelton or turgo I might get up to 80% but: the equipment cost would be much higher and I would lose the benefit of 10' of suction head going down the discharge pit. The trick is to match the pump/turbine to the head and 'design' flow. See: EnergyIndependence-Rob.Blogspot.com for much more? info.
By: svedr. on 25 Apr 12, 17:28:13
very nice and carefully designed sistem, but i would say it would be very good to invest in pelton wheel, because with that kind of head and flow characteristics you could get a loooot more? than 20kW
By: nafcd. on 28 Mar 12, 09:12:55
you arent worried about using pvc piping in relation to water hammer. i have seen that shatter pvc. i guess it? wouldnt be a problem as long as no air can enter the system at the intake or you run out of water. very impressive system though
By: hmpeter. on 29 Feb 12, 19:47:39
Very impressive!?
By: ownerheard. on 11 Feb 12, 17:07:00
I Love The Video It Can Increase My Knowledge Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator ?
By: ayamsory. on 11 Feb 12, 15:50:27
Good, I like that? you share this video, I wish success always Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
By: Destayear. on 11 Feb 12, 14:56:19
Nice Video That You Share , So Very Nice Thanks You here is 210 feet of head (92 PSI) and 550 ft of 8 inch welded steel penstock. We can draw? 2500 gal /minute and still maintain about 85 PSI
By: cTianroy. on 11 Feb 12, 14:12:42
I Really Like The Video From Your This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single? phase Generators.
By: anakmudajaman. on 11 Feb 12, 13:35:56
Your Video Is Very Useful Sharing There is 210 feet of head (92 PSI) and 550 ft of 8 inch welded steel penstock. We can draw 2500 gal /minute? and still maintain about 85 PSI.
By: thoorblood. on 08 Feb 12, 23:27:06
good ? enginer what think you can do bery big this sistem i have plains for 1'5mw or more
By: HungryGreeny. on 09 Dec 11, 22:23:28
Thanx? for your answers!
By: Honders. on 09 Dec 11, 22:05:46
, The grid is like a freight train, my little generator is like a person pushing on the back. The train (grid) speed (voltage/frequency) will be the same no matter if I push or not, or whether? it is loaded down with 100 cars or 110 cars.
By: HungryGreeny. on 09 Dec 11, 15:17:32
Hm, then i have another question - why grid connected generators automatically stabilized? Grid also don't have constant? load isn't it?
By: Honders. on 09 Dec 11, 12:23:31
Yes, the load controllers act more rapidly to keep the voltage in check. The frequency feedback loop is slower acting but keeps the? long term stability of the frequency in check. Grid connected generators are automatically stabilized by the grid and don't need these controls.
By: HungryGreeny. on 09 Dec 11, 10:59:05
So, why there is dump load controller? I thought destination of dump load is to provide constant load on the? generator, and? thereby maintain constant rpm, and constant frequency. Where is my misunderstanding?
By: Honders. on 09 Dec 11, 02:28:25
, It? has a frequency feedback loop. If frequency drifts up the valve closes some, if frequency goes down the water valve is opened very slowly.
By: HungryGreeny. on 08 Dec 11, 23:41:19
How it's maintain constant? frequency?
By: MrJgodwin. on 02 Dec 11, 03:12:20
How many volts? were you pumping out ?
By: douro20. on 07 Nov 11, 19:46:26
How? much power are you generating?
By: truckinjeff. on 02 Oct 11, 19:33:58
How do you monitor and control the voltage and? phasing of the generators?
By: Ali2011mb. on 10 Aug 11, 00:35:21
Excellent video. See my channel electric motor new design.?